| Name | EILDON REGULATING DAM |
|---|---|
| Secondary Dam | No |
| Main Dam | |
| Reservoir Name | EILDON REGULATING DAM |
| Purposes | |
| Owner/Operator Name | AGL |
| Consultant Name | State Electricity Commission, Victoria |
| Contractor Name | State Electricity Commission, Victoria |
| Comment One | Regulating dam required for operation of Eildon hydroelectric power station (120MW), Pacific Blue operating small 4MW hydroelectric turbine from Eildon regulating dam |
| Comment Two | |
| URL | |
| PSP | |
| Electrical Power (MW) | |
| Mean Annual Energy (GWh) | |
| Resettlement |
| Alternative Name | |
| National Code | |
| Dam Code | |
| Nb References ICOLD | |
| References ICOLD | |
| Reserved Committee O |
| Continent | AUSTRAL-ASIA |
| Country Name | Australia |
| French Country Name | |
| International | |
| River | Goulburn River |
| City | Eildon |
| State | VIC |
| Longitude | 145.899017 |
| Latitude | -37.245028 |
| Zone ISO 3166 | AU |
| Built | 1957 |
| Particular | |
| Dam Type | TE earthfill dam |
| Sealing | |
| Foundation | |
| Height (m) | 12.0 |
| Length (m) | 497.0 |
| Spillway Capacity (m³/s) | 3490.0 |
| Spillway Type | V |
| Detailed Type of Dam | |
| Elevation (m) | 217 |
| Volume Dam (1,000m³) | |
| Reservoir Volume (1,000m³) | 5370 |
| Reservoir Area (1,000m²) | 1200 |
| Reservoir Length (km) | |
| Catchment (km²) | 21.0 |
| Irrigated Area (km²) | |
| Flood Protect (% of reservoir volume) | |
| Sedimentation | |
| Reservoir Code | |
| Reservoir ISO 3166 |
No images available.